Bioreactor Off-Gas Condensers

Water out of fermenter exhaust before the sterile vent filter

Contact us

Heat Exchangers For

Drying Bioreactor Exhaust Ahead of the Vent Filter

Aerobic fermenters and cell-culture bioreactors sparge air, oxygen and sometimes nitrogen through the broth, and that gas leaves saturated with water at the culture temperature and carrying carbon dioxide from respiration. It exits at only a few psig. If the water condenses in the hydrophobic sterile vent filter, the filter wets out, back pressure climbs, and the sterile boundary of the batch is at risk. The off-gas condenser exists to drop the dew point before the gas reaches that filter.

The fitting construction is a vertical Fixed Tubesheet shell and tube unit with gas flowing down the tubes and condensate draining by gravity, built to be steam-sterilized in place with the vessel. A Welded Plate unit is a poor choice here even though it is compact: its narrow channels add pressure drop the vessel cannot spare, it is difficult to sterilize and drain completely, and it cannot be inspected. We would steer this duty to the shell and tube design.

Size starts from gas flow, which is the sparge rate times the working volume, plus vessel temperature, head pressure, the chilled water or glycol available and the sterilization conditions the unit must withstand.

Request a Quote
stainless process piping and pressure gauges on an exhaust line, where a bioreactor off-gas process condenser is installed
Emissions Control – spiral condenser icon Emissions Control
Vacuum Duty icon Vacuum Duty
Noncondensables icon Noncondensables
Condensate Drainage icon Condensate Drainage

Saturated Air With Little Pressure to Spare

Most of the heat removed here is sensible cooling of air and carbon dioxide, with a relatively small latent load from the water. That makes the gas-side film coefficient the controlling resistance and the surface larger than the condensed mass would suggest. The allowable pressure drop is a fraction of a psi, because every bit of drop raises vessel head pressure and changes dissolved oxygen and carbon dioxide behavior in the culture.

Foam is the upset to design for. When antifoam addition falls behind, foam and aerosol climb into the exhaust line and reach the condenser. The tubes knock out much of the droplet load, which protects the filter, but a full foam-out can flood a small unit, so tube diameter and the drain path need margin beyond the steady-state rating.

Setting the Outlet Dew Point

The target is a gas outlet temperature several degrees below the vent filter temperature, usually with an electrically or steam-heated filter housing to keep the membrane above the gas dew point. Chilled water in the 40s F is typical. Microbial fermentations can run high sparge rates and produce more carbon dioxide than mammalian culture, so the same vessel size may need a noticeably larger condenser for a bacterial process.

Why the Vertical Tube Unit Fits

Shell & Tube - Fixed Tubesheet in vertical orientation gives an open gas path with low pressure drop, self-draining tubes, steam-in-place capability with the bioreactor and surfaces that can be inspected during maintenance. Plate Exchanger - Welded Plate concentrates surface in narrow channels that suit liquid-liquid duty better than a low-pressure saturated gas, so it fits elsewhere in a biologics plant, not on this vent.

What a Dry Vent Filter Protects

A wetted vent filter is one of the more common reasons a long culture run is put at risk. Keeping the membrane dry preserves gas flow, holds head pressure where the control strategy expects it and extends filter life between changes.

Over a run of several weeks, especially in perfusion, the water carried out by dry sparge gas adds up. Returning condensate limits volume loss and keeps media and product concentration from drifting upward over the course of the batch.

Building to the Sterile Boundary

Process-side surfaces are 316L to ASME BPE practice: orbital welds, polished product-contact surfaces, sloped drainable geometry and sanitary clamp connections. The unit must be rated for sterilization temperature and pressure as well as normal operation, and the shell side must tolerate the thermal cycle of each steam-in-place. Elastomers are EPDM or platinum-cured silicone with USP Class VI documentation.

Return to the Vessel or Send to Drain

Returning condensate to the bioreactor keeps volume and is the default for most processes, provided the return leg stays inside the sterile boundary. Some sites drain it instead, through a steam-sealed sterile drain, when the condensate carries foam, antifoam or material they would rather not return. Either way, place the back-pressure control valve after the vent filter, and make sure the condensate leg can not hold up liquid that seals off the gas path.

Related

gauges and valves on a process line in warm plant lighting, where a solvent recovery process condenser is installed

PHARMACEUTICAL • MARKET

Solvent Recovery (Pharma)

Recovered IPA, acetone, THF or DCM must meet spec to go back into a GMP process. The condenser sets how much you recover and how clean it is.

+ Learn More
insulated process piping and valves in a plant, where an API manufacturing process condenser is installed

PHARMACEUTICAL • MARKET

API Manufacturing

Reactor reflux, vacuum crystallizer concentration and filter dryer solvent pull each need a condenser that fits the validated train under GMP.

+ Learn More
Pharmaceutical condensers

PHARMACEUTICAL • OVERVIEW

Pharmaceutical

Pharma condensers face validation, solvent specs and sterile boundaries more than thermal limits. Materials and design for regulated duties.

+ Learn More

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Engineering - Sales